State-of-the-art area monitoring – the Dräger X-zone® 5500 in combination with the Dräger X-am® 5000, 5100 or 5600 gas detection instruments can be used for the measurement of up to six gases and extends the portable gas detection technology to a comprehensive system with many applications.
• Innovative area monitoring
• Clear warning
• Wireless fence line
• Continuous operation for up to 120 hours
• 360°-gas entry
• inductive charging station: easy and convenient non-contact charging
• Data interface mod bus
• Secure area monitoring
The application fields of our mobile gas detection devices are diverse as your daily work, no matter in which industry. Use it for personal workplace monitoring, clearance measurement of confined spaces, leakage detection, area monitoring and much more.
Dimensions (W x H x D)
490 x 300 x 300 mm
Weight
10 kg (22 lbs.) (24 Ah battery)
Ambient conditions
Temperature max. +50 °C; max.
122 °F Pressure 700 to 1,300 hPa
Humidity 10 to 95 % r.h
Ingress Protection
IP67
Alarm
Visual 360° LED (illuminated ring)
Audible 360°; > 108 dB in a distance of 1 m (30 ft.), 120 dB in a distance of 30 cm (1 ft.)
Configurable alarm patterns, frequencies and volumes
Life signal
Green status display (360°),
illuminated ring (LED)
Operating time
Approx. 120 h (24 Ah battery)
Depending on sensor equipment / configuration of the life signal
Charging time
Approx. 14 h
Flexible power supply: External 100 – 240 V charger (worldwide) or inductive wireless charger
Pump operation
Maximum hose length: 45 m (150 ft.), 30 m (100 ft.) for zone 0
Alarm output
Potential-free alarm contact for intrinsically safe circuits (6-pole); < 20 V to 0.25 A (0.15 A constant current); Resisting load
Radio transmission
Worldwide license-free ISM frequencies
Digital radio, robust and interference-free transmission up to 100 m (656 ft.)
ATEX-I M1 Ex ia I Ma
II 1G Ex ia IIC T3 Ga
II 2G Ex ia d IIC T4 Gb
IECEX-Ex ia IIC T3 Ga
Ex ia d IIC T4 Gb
Ex ia I Ma
CSA/US-Class I, zone 0, A/Ex ia IIC T3 /Ga
Class I, zone 1, A/Ex ia d IIC T4 /Gb