Dräger provides single gases and gas mixtures of reliable, constant quality. These are available in a range of different size cylinders. Each cylinder includes a certificate of analysis confirming the respective gas concentration. The standard four gas combination will be as below,
15PPM H2S 50PPM CO 2.5% CH4 18% O2, Balance N2
• Certified single gas and gas mixtures
• Tailor-made for Dräger gas measuring devices
• Recyclable cylinders
• All Dräger pressure regulators are adjusted to the optimal flow for Dräger devices.
• Especially designed for Dräger X-dock® and Bump Test Station
Calibration of equipment will ensure safe operation and functionality of equipment and will also meet with the applicable regulations and codes of practice.
Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.
Dräger-Tubes represent one of the classic forms of gas analysis. These versatile tubes make possible countless applications in industry, firefighting, disaster prevention, laboratory work, environmental protection and many other areas which require measurement results to be instantly available so that decisions can be made.
Dimensions (W x H x D)
170 x 45 x 85 mm
Stroke volume
100 ± 5 cm3
Weight
250 g
Air humidity
Relative humidity: 0 – 95% non-condensing
Temperature
-20 °C to +50 °C
Approvals
CE-certified (EN 0158)
ATEX I M1
II 1GD IIB 85°C T6
II 2G IIC T6
-20 °C ≤ Ta ≤ +50 °C
DIN EN ISO 17621
By using the Dräger Aerotest Simultan HP, the quality of the breathing air from a compressor or a compressed air cylinder can be tested. The application of the test system ensures the reliable testing in accordance with the purification standard EN 12 021.
The Dräger Aerotest Simultan HP enables the quantitative detection of various potentially harmful substances, e.g. carbon monoxide, carbon dioxide, water vapor and oil in dispersing compressed air. The values can either be determined individually or simultaneously.
• Results are directly shown at the end of the measurement process
• Short measurement time: between 5 seconds to 15 minutes
• Quick and targeted measurements
• Easy handling
• Flexible use
• Measurements of compressed air / compressed gases
• The measuring instrument can be connected to the high-pressure air network. It takes five minutes until the Aerotest displays an indication about the degree of contamination of the filled breathing air.
Gas detector tubes are one of the classic measurement methods used for gas analysis today. This versatile system can be used in numerous applications in industry, firefighting and disaster management, in the laboratory, marine, for environmental protection and in many other areas.
Using Drager benzene gas detection tubes you can measure rom 0.5 to 420 ppm.Dräger sampling tubes and systems measuring complex compounds and mixtures of substances, to manual and automatic tube pumps.
• Results are directly shown at the end of the measurement process
• Short measurement time: between 5 seconds to 15 minutes
• Quick and targeted measurements
• Easy handling
• Flexible use
• Air examinations at the workplace in the range of legal limit values
• Technical gas analysis in the areas of emission concentrations
• Measurements of compressed air / compressed gases
Benzene 0.5/a
Range – 0.5 to 10 ppm
Number of Strokes – 15
Part Number – 67 28 561
Benzene 0.5/c (5)
Range – 0.5 to 10 ppm
Number of Strokes – 20
Part Number – 81 01 841
Benzene 2/a (5)
Range – 2 to 60 ppm
Number of Strokes – 8
Part Number – 81 01 231
Benzene 5/a
Range – 5 to 40 ppm
Number of Strokes – 3
Part Number – 67 18 801
Benzene 5/b
Range – 5 to 50 ppm
Number of Strokes – 8
Part Number – 67 28 071
Benzene 15/a
Range – 15 to 420 ppm
Number of Strokes – 4
Part Number – 81 01 741
Gas detector tubes are one of the classic measurement methods used for gas analysis today. This versatile system can be used in numerous applications in industry, firefighting and disaster management, in the laboratory, marine, for environmental protection and in many other areas. Using Drager CO2 gas detection tubes you can measure 100-3000 ppm or 0.5 – 60% volume.
• Results are directly shown at the end of the measurement process
• Short measurement time: between 5 seconds to 15 minutes
• Quick and targeted measurements
• Easy handling
• Flexible use
• Air examinations at the workplace in the range of legal limit values
• Technical gas analysis in the areas of emission concentrations
• Measurements of compressed air / compressed gases
Carbon Dioxide 100/a
Range – 100 to 3000 ppm
Number of Strokes – 4
Part Number – 81 01 811
Carbon Dioxide 0.1%/a
Range – 0.5 to 6 Vol% – 0.1 to 1.2 Vol%
Number of Strokes – 30 – 2
Part Number – CH23 501
Carbon Dioxide 0.5%/a
Range – 0.5 to 10 Vol%
Number of Strokes – 30
Part Number – CH31 401
Carbon Dioxide 1%/a
Range – 1 to 20 Vol%
Number of Strokes – 30
Part Number – CH25 101
Carbon Dioxide 5%/A
Range – 5 to 60 Vol%
Number of Strokes – 2
Part Number – CH20 301
Gas detector tubes are one of the classic measurement methods used for gas analysis today. This versatile system can be used in numerous applications in industry, firefighting and disaster management, in the laboratory, marine, for environmental protection and in many other areas. Using CO gas detection tube you can measure from 2- 3000 ppm or
0.3 -7 % volume
• Results are directly shown at the end of the measurement process
• Short measurement time: between 5 seconds to 15 minutes
• Quick and targeted measurements
• Easy handling
• Flexible use
• Air examinations at the workplace in the range of legal limit values
• Technical gas analysis in the areas of emission concentrations
• Measurements of compressed air / compressed gases
Carbon Monoxide 2/a
Range – 2 to 60 ppm
Number of Strokes – 4
Part Number – 67 33 051
Carbon Monoxide 5/c
Range – 100 to 700 ppm – 5 to 150 ppm
Number of Strokes – 50s – 4
Part Number – CH25 601
Carbon Monoxide 8/a
Range – 8 to 150 ppm
Number of Strokes – 2
Part Number – CH19 701
Carbon Monoxide 10/d
Range – 100 to 3000 ppm – 10 to 300 ppm
Number of Strokes – 40s – 6
Part Number – 81 03 321
Carbon Monoxide 10/b
Range – 100 to 3000 ppm – 10 to 300 ppm
Number of Strokes – 20s – 3
Part Number – CH20 601
Carbon Monoxide 10/c
Range – 10 to 250 ppm
Number of Strokes – 1
Part Number – 81 01 951
Carbon Monoxide 0.3%/b
Range – 0.3 to 7 Vol%
Number of Strokes – 30
Part Number – CH29 901
Gas detector tubes are one of the classic measurement methods used for gas analysis today. This versatile system can be used in numerous applications in industry, firefighting and disaster management, in the laboratory, marine, for environmental protection and in many other areas. Using Drager H2S gas detection tubes you can measure 0.2 – 2000 ppm or 0.2 to 40% volume.
• Results are directly shown at the end of the measurement process
• Short measurement time: between 5 seconds to 15 minutes
• Quick and targeted measurements
• Easy handling
• Flexible use
• Air examinations at the workplace in the range of legal limit values
• Technical gas analysis in the areas of emission concentrations
• Measurements of compressed air / compressed gases
Hydrogen Sulphide 0.2/a
Range – 0.2 to 5 ppm
Number of Strokes – 5
Part Number – 81 01 461
Hydrogen Sulphide 0.2/b
Range – 0.2 to 6 ppm
Number of Strokes – 55s
Part Number – 81 01 991
Hydrogen Sulphide 0.5/a
Range – 0.5 to 15 ppm
Number of Strokes – 6
Part Number – 67 28 041
Hydrogen Sulphide 1/c
Range – 10 to 200 ppm – 1 to 20 ppm
Number of Strokes – 20s – 3
Part Number – 67 19 001
Hydrogen Sulphide 1/d
Range – 10 to 200 ppm – 1 to 20 ppm
Number of Strokes – 1 – 10
Part Number – 81 01 831
Hydrogen Sulphide 2/a
Range – 20 to 200 ppm – 2 to 20 ppm
Number of Strokes – 20s – 3
Part Number – 67 28 821
Hydrogen Sulphide 2/b
Range – 2 to 60 ppm
Number of Strokes – 30s
Part Number – 81 01 961
Hydrogen Sulphide 5/b
Range – 5 to 60 ppm
Number of Strokes – 4
Part Number – CH29 801
Hydrogen Sulphide 100/a
Range – 100 to 2000 ppm
Number of Strokes – 30s
Part Number – CH29 101
Hydrogen Sulphide 0.2%/A
Range – 0.2 to 7 Vol%
Number of Strokes – 2
Part Number – CH28 101
Hydrogen Sulphide 2%/a
Range – 2 to 40 Vol%
Number of Strokes – 1
Part Number – 81 01 211
Gas detector tubes are one of the classic measurement methods used for gas analysis today. This versatile system can be used in numerous applications in industry, firefighting and disaster management, in the laboratory, marine, for environmental protection and in many other areas.Using Drager mercaptan gas detection tube you can measure
0.1 to 100 ppm.
• Results are directly shown at the end of the measurement process
• Short measurement time: between 5 seconds to 15 minutes
• Quick and targeted measurements
• Easy handling
• Flexible use
• Air examinations at the workplace in the range of legal limit values
• Technical gas analysis in the areas of emission concentrations
• Measurements of compressed air / compressed gases
Mercaptan 0.1a
Range – 0.1 to 2.5 ppm
Number of Strokes – 10
Part Number – 81 03 281
Mercaptan 0.5/a
Range – 0.5 to 5 ppm
Number of Strokes – 5
Part Number – 67 28 981
Mercaptan 20/a
Range – 20 to 100 ppm
Number of Strokes – 2s
Part Number – 81 01 871
The Dräger Pac® 6000 disposable personal gas detector measures CO, H2S,
SO2 or O2 reliably and precisely, even in the toughest conditions. The robust
design, quick sensor response times, and a powerful battery ensure maximum
safety for up to two years with virtually no maintenance required.
• Strong performance for maximum safety
• Easy handling.
• Robust design – even for the toughest conditions
• User-friendly display with all important information
• 360° alarm with various functions
• Data logger and event logger for analyses and reports
• Economical operating costs
• Fast function test saves time and money
Portable gas detectors are mobile since they are carried on or by personnel. They are used by anyone who is entering a confined space, or where there’s the potential for the presence of a dangerous gas or a lack of oxygen. The detector must be placed on the person so that the breathing zone is constantly monitored for safety.
Dimensions (W x H x D)
64 x 84 x 20 mm
Weight
Approx. 106 g (113 g with clip)
Device service life
2 years from first activation
Battery service life
2 years (O2 sensors min. 10 months)
Protection class
IP68
Air pressure
700 to 1,300 hPa
Air humidity
10 to 90% relative humidity, non-condensing
Temperature
-30 °C to +55 °C (briefly down to -40 °C for 1 hr, depending on sensor)
The Drager Pac 6500 is the personal single-gas detection device with unlimited life and measures CO, H2S, SO2 or O2 quickly and precisely. Quick sensor response times and a powerful battery also ensure safety.
• Strong performance for maximum safety.
• Unlimited life for instrument.
• 5 year warranty for H2S sensor.
• No shelf-life limitation.
• Robust design – even for the toughest conditions.
• User-friendly display with all important information.
• 360° alarm with various functions.
• Data logger and event logger for analyses and reports.
• Economical operating costs.
• Fast function test saves time and money.
Portable gas detectors are mobile since they are carried on or by personnel. They are used by anyone who is entering a confined space, or where there is a potential for the presence of a dangerous gas or a lack of oxygen. The detector must be placed on the person so that the breathing zone is constantly monitored for safety.
Dimensions (W x H x D)
64 x 84 x 20 mm
Weight
Approx. 106 g (113 g with clip)
Battery service life
2 years (O2 sensors min. 10 months)
Protection class
IP68
Air pressure
700 to 1,300 hPa
Air humidity
10 to 90% relative humidity, non-condensing
Temperature
-30 °C to +55 °C (briefly down to -40 °C for 1 hr, depending on sensor)
With the robust Dräger Pac® 8000, you’ll be well equipped for tough conditions: this non-disposable, personal single-gas detection device is a reliable and precise instrument, which detects hazardous concentrations of 29 different gases, including special gases like NO2, O3 or COCl2.
• Unlimited operating time and there is no shelf-life limitation..
• Sensors for special gases NO,CO2,Cl2,HCN,NH3,PH3,OV,NO2,Phosgene.
• Robust design – even for the toughest conditions.
• Easy handling.
• User-friendly display with all important information.
• 360° alarm with various functions
• Data logger and event logger for analyses and reports
• Economical operational costs
• Fast function test saves time and money
Portable gas detectors are mobile since they are carried on or by personnel. They are used by anyone who is entering a confined space, or where there’s the potential for the presence of a dangerous gas or a lack of oxygen. The detector must be placed on the person so that the breathing zone is constantly monitored for safety.
Dimensions (W x H x D)
64 x 84 x 20 mm
Weight
Approx. 106 g (113 g with clip)
Battery service life
2 years
Protection class
IP68
Air pressure
700 to 1,300 hPa
Air humidity
10 to 90% relative humidity, non-condensing
Temperature
-30 °C to +55 °C (briefly down to -40 °C for 1 hr, depending on sensor)
The Dräger Pac® 8500 single-gas detection device is a reliable and precise instrument even under the toughest of conditions. The detector can be equipped with a hydrogen-compensated CO sensor or Dräger dual sensor.The dual sensors provide the option of measuring two gases at once: either H2S with CO or O2 with CO.
• Unlimited operating time and there is no shelf-life limitation.
• Two gas detection in a single-gas device, either H2S with CO or O2 with CO. Or with a hydrogen-compensated CO sensor
• Measurement of carbon monoxide with significantly reduced cross sensitivity
• Robust design – even for the toughest conditions
• Easy handling.
• User-friendly display with all important information
• 360° alarm with various functions
• Economical operating costs
• Fast function test saves time and money
Portable gas detectors are mobile since they are carried on or by personnel. They are used by anyone who is entering a confined space, or where there’s the potential for the presence of a dangerous gas or a lack of oxygen. The detector must be placed on the person so that the breathing zone is constantly monitored for safety.
Dimensions (W x H x D)
64 x 84 x 20 mm
Weight
Approx. 106 g (113 g with clip)
Battery service life
2 years (O2 and dual sensors min. 12 months))
Protection class
IP68
Air pressure
700 to 1,300 hPa
Air humidity
10 to 90% relative humidity, non-condensing
Temperature